INTRODUCTION TO NBT-2B SERIES
|
| |
FEATURES

Excellent attenuation for both normal mode and commom mode
In/output employ the terminal block
Good reliability and high performance
|
| |
APPLICATION
Switching power supplies with high voltage
Numerical control machines
Industrial machines
|
| |
SHAPE AND DIMENSIONS
|
SHAPE AND DIMENSIONS
|
| MODEL |
NBT-2B40 |
NBT-2B50 |
NBT-2B60 |
NBT-2B80 |
NBT-2B100 |
| A |
210 |
210 |
210 |
210 |
225 |
| B |
235 |
235 |
235 |
235 |
250 |
| C |
250 |
250 |
250 |
250 |
265 |
| D |
90 |
90 |
90 |
90 |
90 |
| E |
120 |
120 |
120 |
120 |
120 |
| F |
80 |
80 |
80 |
80 |
80 |
| G |
6.5 |
6.5 |
6.5 |
6.5 |
6.5 |
|
SPECIFICATIONS

| MODEL |
NBT-2B40 |
NBT-2B50 |
NBT-2B60 |
NBT-2B80 |
NBT-2B100 |
| Rated Voltage AC(V) |
250 |
250 |
250 |
250 |
250 |
| Rated Current AC(A) |
40 |
50 |
60 |
80 |
100 |
Tested Voltage AC(V) One Minute, Line to Earth |
2000 |
2000 |
2000 |
2000 |
2000 |
Insulation Resistance (MΩ) 500V DC One Minute, Line to Earth |
≥500 |
≥500 |
≥500 |
≥500 |
≥500 |
Leakage Current (mA) 250V-60Hz |
≤3.5 |
≤3.5 |
≤3.5 |
≤3.5 |
≤3.5 |
| Voltage Drop(V) |
≤1.0 |
≤1.0 |
≤1.0 |
≤1.0 |
≤1.0 |
| Temperature Rise(deg.) |
≤30 |
≤30 |
≤30 |
≤30 |
≤30 |
Operating Temperature Range(℃) |
-25 ~+85 |
-25 ~+85 |
-25 ~+85 |
-25 ~+85 |
-25 ~+85 |
NOTE
: Operating Temperature Range - Including temperature Rise