INTRODUCTION TO NFK-T SERIES
|
| |
FEATURES

Suitable for the products that must confirm to FCC, FTZ regulations.
Excellent attenuation for both normal mode and common mode
Compact size and economical
Use of fasten tabs facilitate filter assembly (Fasten tab#110 or #250)
|
| |
APPLICATION
ECRs and electronic scales
Numerical control equipment
Measuring instruments and various other electronic equipment
Digital equipment
|
| |
SHAPE AND DIMENSIONS
|
SPECIFICATIONS

| MODEL |
NFK-102T |
NFK-103T |
NFK-104T |
NFK-106T |
| Rated Voltage AC(V) |
250 |
250 |
250 |
250 |
| Rated Current AC(A) |
2 |
3 |
4 |
6 |
Tested Voltage AC(V) One Minute, Line to Earth |
2000 |
2000 |
2000 |
2000 |
Insulation Resistance (MΩ) 500V DC One Minute, Line to Earth |
≥300 |
≥300 |
≥300 |
≥300 |
Leakage Current (mA) 250V-60Hz |
≤0.5 |
≤0.5 |
≤0.5 |
≤0.5 |
| Voltage Drop(V) |
≤1.5 |
≤1.5 |
≤1.5 |
≤1.5 |
| Temperature Rise(deg.) |
≤30 |
≤30 |
≤30 |
≤30 |
Operating Temperature Range(℃) |
-25 ~+85 |
-25 ~+85 |
-25 ~+85 |
-25 ~+85 |
NOTE
: Operating Temperature Range - Including temperature Rise
※ Y capacitor alternative(2200pF, 3300pF)