INTRODUCTION TO NFK-W SERIES
|
| |
FEATURES

Suitable for the products that must confirm to FCC, FTZ regulations.
Excellent filtering characteristic for both normal mode and common mode
High safety and reliability
Thy case is insulated and equipped with ground wire(UL 1015, AWG#18)
|
| |
APPLICATION
ECRs and electronic scales
POS and control devices
Measuring instruments and various other electronic devices
|
| |
SHAPE AND DIMENSIONS
|
SPECIFICATIONS

| MODEL |
NFK-102W |
NFK-103W |
NFK-104W |
NFK-106W |
| Rated Voltage AC(V) |
250 |
250 |
250 |
250 |
| Rated Current AC(A) |
2 |
3 |
4 |
6 |
Tested Voltage AC(V) One Minute, Line to Earth |
2000 |
2000 |
2000 |
2000 |
Insulation Resistance (MΩ) 500V DC One Minute, Line to Earth |
≥300 |
≥300 |
≥300 |
≥300 |
Leakage Current (mA) 250V-60Hz |
≤0.5 |
≤0.5 |
≤0.5 |
≤0.5 |
| Voltage Drop(V) |
≤1.5 |
≤1.5 |
≤1.5 |
≤1.5 |
| Temperature Rise(deg.) |
≤30 |
≤30 |
≤30 |
≤30 |
Operating Temperature Range(℃) |
-25 ~+85 |
-25 ~+85 |
-25 ~+85 |
-25 ~+85 |
NOTE
: Operating Temperature Range - Including temperature Rise
※ Y capacitor alternative(2200pF, 3300pF)
ATTENUATION CHARACTERISTIC
|