INTRODUCTION TO NFM-H SERIES
|
| |
FEATURES

Suitable for the products that must confirm to FCC, FTZ regulations.
Excellent attenuation for both normal mode and common mode
Compact and economical
Low leakage current
Good shield effect by using metal case
|
| |
APPLICATION
Computer and peripherals
Measuring instruments
Office automation devices and various other industrial devices
Suitable for the FA equipment
Digital equipment
|
| |
SHAPE AND DIMENSIONS
|
SPECIFICATIONS

| MODEL |
NFM-205H |
NFM-210H |
NFM-215H |
NFM-220H |
NFM-230H |
| Rated Voltage AC(V) |
250 |
250 |
250 |
250 |
250 |
| Rated Current AC(A) |
5 |
10 |
15 |
20 |
30 |
Tested Voltage AC(V) One Minute, Line to Earth |
2000 |
2000 |
2000 |
2000 |
2000 |
Insulation Resistance (MΩ) 500V DC One Minute, Line to Earth |
≥300 |
≥300 |
≥300 |
≥300 |
≥300 |
Leakage Current (mA) 250V-60Hz |
≤0.5 |
≤0.5 |
≤0.5 |
≤0.5 |
≤0.5 |
| Voltage Drop(V) |
≤1.0 |
≤1.0 |
≤1.0 |
≤1.0 |
≤1.0 |
| Temperature Rise(deg.) |
≤30 |
≤30 |
≤30 |
≤30 |
≤30 |
Operating Temperature Range(℃) |
-25 ~+85 |
-25 ~+85 |
-25 ~+85 |
-25 ~+85 |
-25 ~+85 |
NOTE
: Operating Temperature Range - Including temperature Rise
ATTENUATION CHARACTERISTIC
|
CIRCUIT DIAGRAMS
|
|