INTRODUCTION TO NFZ-SG SERIES
|
| |
FEATURES

Suitable for the products that must confirm to FCC, FTZ regulations.
Excellent filtering characteristic for both normal mode and common mode(AC450V, 30A~200A)
Outstanding noise absorption, particularly for high voltage impulse
Two stage for excellent filtering characteristics
Safety standard approved for EU market(TUV:R9755193)
Safety cover for terminal
|
| |
APPLICATION
Industrial machinery
AVR, UPS, Inverters
NC machine, CNC machine
Robot
For equipment requiring very high noise attenuation
|
| |
SHAPE AND DIMENSIONS
|
| MODEL |
NFZ-4030SG |
NFZ-4040SG |
NFZ-4050SG |
NFZ-4060SG |
NFZ-4150SG |
NFZ-4200SG |
| A |
200 |
200 |
200 |
200 |
320 |
320 |
| B |
220 |
220 |
220 |
220 |
350 |
350 |
| C |
240 |
240 |
240 |
240 |
380 |
380 |
| D |
320 |
320 |
320 |
320 |
490 |
490 |
| E |
80 |
80 |
80 |
80 |
110 |
110 |
| F |
100 |
100 |
100 |
100 |
135 |
135 |
| G |
120 |
120 |
120 |
120 |
160 |
160 |
| H |
20 |
20 |
20 |
20 |
30 |
30 |
| I |
50 |
50 |
50 |
50 |
65 |
65 |
| J |
90 |
90 |
90 |
90 |
120 |
120 |
| K |
40 |
40 |
40 |
40 |
52.5 |
52.5 |
| L |
6.5 |
6.5 |
6.5 |
6.5 |
6.5 |
6.5 |
| M |
M6 |
M6 |
M6 |
M6 |
M12 |
M12 |
| N |
M6 |
M6 |
M6 |
M6 |
M8 |
M8 |
SHAPE AND DIMENSIONS
|
| No. |
NFZ-4100SG |
NFZ-4080SG |
| A |
6-M10BOLT |
M8 |
| B |
6-M8BOLT |
M8 |
|
SPECIFICATIONS

| MODEL |
NFZ-4030SG |
NFZ-4040SG |
NFZ-4050SG |
NFZ-4060SG |
NFZ-4080SG |
NFZ-4100SG |
NFZ-4150SG |
NFZ-4200SG |
Rated Voltage AC(V) |
450 |
450 |
450 |
450 |
450 |
450 |
450 |
450 |
Rated Current AC(A) |
30 |
40 |
50 |
60 |
80 |
100 |
150 |
200 |
Tested Voltage AC(V) One Minute, Line to Earth |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
Insulation Resistance (MΩ) 500V DC One Minute, Line to Earth |
≥500 |
≥500 |
≥500 |
≥500 |
≥500 |
≥500 |
≥500 |
≥500 |
Leakage Current (mA) 250V-60Hz |
≤3.5 |
≤3.5 |
≤3.5 |
≤3.5 |
≤3.5 |
≤3.5 |
≤3.5 |
≤3.5 |
| Voltage Drop(V) |
≤1.0 |
≤1.0 |
≤1.0 |
≤1.0 |
≤1.0 |
≤1.0 |
≤1.0 |
≤1.0 |
Temperature Rise(deg.) |
≤40 |
≤40 |
≤40 |
≤40 |
≤40 |
≤40 |
≤40 |
≤40 |
Operating Temperature Range(℃) |
-25 ~+85 |
-25 ~+85 |
-25 ~+85 |
-25 ~+85 |
-25 ~+85 |
-25 ~+85 |
-25 ~+85 |
-25 ~+85 |
NOTE
: Operating Temperature Range - Including temperature Rise
ATTENUATION CHARACTERISTIC
|